Impact of two lead plates computed with the two codes, with commentary.
1. The Test
Two lead plates, 32.4 mm thick, collide at ±227 m/s. A shock wave starts from the contact plane and runs into each plate. Behind it the lead is stopped and compressed to about 6 GPa. When the shock reaches the free surface, a release wave comes back and sends the lead away from the impact plane.
This is the compression counterpart of the release (tension) test in lead. Together, the two tests check how both codes handle compression, tension and the energy exchanged between them, before the copper Taylor anvil.
2. The Codes
The same two Eulerian codes developed at TCHIKOU-R CONSULTING are compared: a diffuse-interface multiphase code, in 1D and in its new 2D axisymmetric version, and a reference-map Eulerian code (2D), in which the plastic history is stored on an adaptive reference grid linked to the current grid through a transported reference map.
The numerical settings are those of the release test: CFL 0.3, Heun (RK2) time stepping, HLLC fluxes, MUSCL reconstruction with a minmod limiter (θ = 1), THINC sharpening (β = 2.5) on the volume fractions in the diffuse-interface code. Lead is a stiffened gas (γ = 4.716, P∞ = 9.676 GPa, ρ₀ = 11 340 kg/m³) with hyperelastic shear (μ = 8.6 GPa), a yield stress of 13.1 MPa and a spall strength of 1 GPa.
| Code | Initial mesh (0.1 mm cells) |
|---|---|
| Diffuse-interface code, 1D | 2500 cells (two plates and air) |
| Diffuse-interface code, 2D | 1 × 1000 cells (one plate against a symmetry plane) |
| Reference-map code, 2D | 4 × 500 cells (0.5 × 0.1 mm, one plate against a symmetry plane) |
| Reference grid | 32 × 32 base cells, automatic refinement up to 7 levels, one cell image per leaf |
Table 1 – Initial meshes.
3. Results

Figure 1 – Shock in the plate at 10 µs: diffuse-interface code in 1D (black) and 2D (red), reference-map code (blue).

Figure 2 – Release wave from the free surface at 20 µs.
| Diffuse-interface 1D | Diffuse-interface 2D | Reference map 2D | Theory | |
|---|---|---|---|---|
| Axial stress behind the shock (MPa) | 6070.8 | 6070.8 | 6070.4 | 6074.7 |
| Rebound velocity at 20 µs (m/s) | 229.0 | 229.0 | 228.3 | – |
Table 2 – Shock stress and rebound velocity. Theory: Rankine-Hugoniot relation of the stiffened gas plus 2/3 of the yield stress.
The three runs agree within 0.07 % with the Rankine-Hugoniot value. The shock travels at 2129 m/s in the frame of the contact plane, as predicted, and reaches the free surface at about 13.75 µs. The 1D and 2D diffuse-interface runs lie on top of each other. The reference map keeps the shock front sharper and gives a slightly steeper release fan, with the same centre and the same rebound velocity.
4. Energy
With the energy-conserving treatment of cavitation and the tensile strength threshold introduced in the release test, the total energy of the diffuse-interface code is conserved to 5 × 10⁻⁷ of the impact kinetic energy over 80 µs, through the impact, the compression, the release and the separation of the plates.
5. Outlook
The comparison stops at 20 µs. After that the plates separate, and the reference-map code still needs the same tensile strength threshold before the two codes can be compared through spall. The next step is the copper Taylor anvil at 227 m/s with both codes.
6. Contact
Dr Serge B. Ndanou, TCHIKOU-R CONSULTING – [email protected]
Explore additional simulations, scientific investigations, and computational engineering projects in our Research & Projects collection.